| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
Summary. Androstenedione and testosterone were measured by radioimmunoassay after chromatography on micro-columns of Lipidex-5000 in jugular plasma samples taken every 2–3 h at the time of luteolysis and oestrus in 3 dairy cows. The concentrations of androstenedione and testosterone varied between 5 and 60 pg/ml and 5 and 80 pg/ml respectively and no consistent pattern in the fluctuations of either steroid was observed.
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |